Resources
FAQS
Browse common questions about Val-Co products and services.
Cremators
Why will the burner only run for a few seconds?
- Not properly grounded. Install a ground rod next to unit.
- Low voltage from power source. Unit may be too far away from power source.
Why am I getting a Probe Fail error?
- The wires to the Heat Probe may be damaged. Remove the Heat Probe plug and place a jumper wire in the 2 connectors of the female plug. If error goes away, the Heat Probe needs to be replaced. If error does not go away, the wires and/or female plug needs to be replaced.
Why is there no fuel spraying on an oil burner?
- Fuel pump is not properly tightened to the drive coupler.
- Fuel pump is not functioning properly; replace pump. (Never run the unit with no fuel available, pump will become damaged.)
Why will my gas burner not light?
- Electrodes are dirty and/or damp. Dry and clean the electrodes.
- Air from blower is not activating Pressure Switch. Check pressure switch tube for obstructions.
How long will a nozzle last on an oil burner?
- Nozzles should be replaced every 500 gallons.
Scales
How do I get the basic and graph code for my Sentinel Scale controller to log in using Optilink?
- Please call us at 1-888-673-2460 for codes. International customers may call (+1) 419-678-8731, ext 9. Serial number from control will be needed.
How can I view the installer setting for the scale?
- Go to the general settings in the installer menu and find the installer setting info page in the general setting and change to Visible.
What is a 24V frequency alarm telling me?
- Possible short in load cell wiring or incorrect wiring.
What is a “No Signal from Scale” telling me?
- Possible short or incorrect wiring to load cell.
Why will my PC not connect to the scale using Optilink?
- Wrong COM port selected in Optilink.
- Correct drivers are not installed in PC to connect to the scale head.
- Baud rate is incorrect in the scale.
- COM ports are faulty in PC.
- COM Board in scale head may be defective.
Where should I place the scale platform in the house?
- Scale platform should be away from large fans and curtain openings where there may be an excessive amount of wind that may cause the scale to sway that may result in false weights. Scale platform is recommended to be placed between a water and a feed line where there is high volume of bird traffic.
I started a new flock and cannot get any weighings from the scale. Why?
- Improper start weight of birds may be entered in the settings of the house, most for house may be turned off, or scale needs to be calibrated.
Infra-radiant Heaters
Why does my brooder not burn correctly?
- Heater needs to be cleaned.
- Insufficient gas pressure going to brooder.
Brooders
Why is soot building up on the brooder?
- Incorrect size gas orifices. Replace orifice with the correct size for the particular brooder pertaining to the gas being used.
- Burner orifice elbow is not directing the gas straight upward. Reposition elbow so that it is pointing straight upward.
Why am I not getting enough heat from the brooder?
- Make sure the orifice is clean. Check the incoming gas pressure. 11″ of water column for LP gas, and 7″ of water column for natural gas.
Tube Heat
Why will the tube heater only run for a few seconds?
- Polarity on the incoming power in incorrect. Reverse L1 and L2 at the power source.
Why will the burner not run and I get pressure switch errors?
- Inlet tubing or blower screen is obstructed.
- Pressure switch needs to be replaced.
Why won’t the igniter glow red?
- Igniter has a crack in it and needs to be replaced.
High Pressure Fog
Why is the compression fitting leaking?
- Fitting may not be properly tightened. Fully insert the tube into the fitting, and hand tighten. With a black marker, make a mark on the tube and the nut to document the position of the nut in relation to the pipe. Then, using 2 properly sized wrenches, turn the nut 1 1/4 turns. No more. No less.
Why are some of the nozzles plugged at start up?
- Keep all of the components as clean as possible during installation. Before installing the automatic drain valve at the end of a fog line, high pressure flush the newly installed system, forcing any foreign debris out of the fog line.
How do I cut the stainless steel pipe?
- Use a tubing cutter with a cutting wheel rated for stainless steel. Do not use any cutting device that produces any shavings (side grinder or chop saw) as steel shavings will plug up the nozzles.
EZ Cool Pad
Why are the joints in the lower trough leaking?
- The couplers were not glued properly. Make sure they apply plenty of glue to both the coupler and the trough when joining the two components.
How do I direct the water from the 1 1/2″ drilled pipe above the pads?
- Direct the water up, and at a slight angle back towards the barn.
Fans
Where do I position the fan blade in relation to the outside edge of the fan orifice on the HyperMAX fan?
- The tips of the fan blades should protrude 1/4″ out of the front of the orifice.
The blade protrudes more on one side of the fan than the other.
- Loosen the four bolts on the motor mounting bracket and pivot the bracket until the blades protrude evenly.
Inlet Actuators and Curtain Machines
How do I adjust the stroke length on a C433 actuator?
- Remove the back cover of the actuator and locate the open/close limit switches. Loosen the small screw so that the topo cam can be turned by hand. Turn the cam clockwise to lengthen the stroke and counterclockwise to shorten the stroke. Each click represents 1/2″ of travel.
Why will the machine run in manual mode but not in automatic mode (230 volt)?
- Control switch is not in automatic mode.
- L1 and L2 wires are reversed.
Why is the clutch slipping, preventing the machine from operating?
- The clutch may need to be adjusted. Refer to manual for instructions to get the proper tolerance between the clutch and the clutch plate.
Why will the ball screw machine not let the curtains drop when power is removed?
- The clutch may need to be adjusted. Refer to the manual for instructions to get the proper tolerance between the clutch and the clutch plate.
Why will the curtain not move manually or automatically?
- Incorrect wiring to the curtain machine.
- Machine may have over-traveled and triggered the kill switch. Trigger the Override Switch and use the Manual Switch to move the curtain.
Controls
Why do all of the sensors on the Ventra 1200 control read N/A?
- Front Board, PA-085-101, needs replaced.
- Improper wiring and/or programming of the sensors.
Why do my heaters turn on when my curtains are down?
- The heater/curtain interlock is not programmed correctly in the temp control settings.
- Heaters not interlocked to correct curtains.
- Curtains are out of calibration.
- Heaters or curtain relay needs to be replaced in control.
- Fault with curtain machine.
Equipment only works in manual and not in auto?
- Toggle switch is in incorrect position. Relay needs to be replaced inside control.
- Animal head count set to 0. Must be above 0 to run in auto.
- Temp control is set to OFF.
Why will fans not turn off when my curtain is down?
- May have an out of position alarm.
- Whisker switch is wired incorrectly.
- Whisker switch programming is incorrect.
How do I flash a memory card?
- Take a card you want programmed in front of a controller that is already programmer, press cancel 3 times, press the down arrow key one time, press the enter button one time, wait for flash message to go away, power down controller, take programmed card out, insert not programmed card, and turn power on.
Why is my language changing to Spanish on a Ventra 1200 controller?
- Decal needs to be replaced with a newer style decal that has a split ribbon.
Why will my feeders not run in auto when it’s between set times?
- Controller is generating feeder ON Time Exceeds alarm that needs to be cleared.
- Clock setting is incorrect.
- Feeder sensor is faulty.
Swine Watering
What do the different colors on the caps of the nipples mean?
- A green cap represents a stainless coil spring is used in the drinker.
- A yellow cap represents a rubber spring is used in the drinker.
Chain Disk Feeding
What is the maximum distance allowed for chain disk?
- Maximum effective length for steel tubes is 1800′ (305m). Each corner equals an effective length of 25′ (7.6m). Can have 24 corners max.
- Continuing styles of sidebar and main content desktop
- Do mobile version
Dedicated Support
Have a question about a VAL-CO® product? Our dedicated support team is standing by to help you get the most out of your VAL-CO products. Use our simple customer support form to contact us today and a VAL-CO representative will respond to your inquiry in a timely fashion.
For immediate Customer Service needs:
Please call 1-800-998-2526 in the US/Canada or (+1) 419-678-8731 internationally. The US call center operates Monday through Friday from 8:00 am to 5:00 pm Eastern (GMT – 4:00).
For immediate Technical Support needs:
Please call 1-888-673-2460. For international technical support, please dial 1-800-998-2526, then press 9. Or email us at Tech-support@dev.group6inc.com.